[. . . ] Electric Dryer PRODUCT MODEL NUMBERS WED4890B, WED4995E 29" Wide Models – Wide opening side-swing door 223/4" (578 mm) 273/4"* (705 mm) 26"** (660 mm) 29" (737 mm) 29" Wide Models – Wide opening hamper door 133/4" (349 mm) 273/4"* (705 mm) 26"** (660 mm) 29" (737 mm) 411/2" (1054 mm) 411/2" (1054 mm) *6. 5 or 7. 0 cu. [. . . ] considered. ■■ Companion appliance spacing should also be 1"/0" (25 mm/0 mm) *Additional spacing recommended W10617663C 02/2015 ELECTRICAL REQUIREMENTS To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz. , AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual branch circuit. VENTING REQUIREMENTS Exhaust venting: Exhaust your dryer to the outside. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. The “Vent System Chart” provides venting requirements that will help achieve best drying performance. Vent System Chart Number of 90° turns or elbows 0 1 2 Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box/louvered hoods 64 ft. (6. 4 m) Exhaust hoods: Recommended Styles: Louvered Hood Box Hood 3 4 Acceptable Style: Vent System Chart (Long Vent Models Only) Angled Hood Number of 90° turns or elbows 0 1 2 3 4 5 Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box/louvered, or Angled hoods 120 ft. (21. 3 m) Determine vent path: ■■ Select route that will provide straightest and most direct path outdoors. ■■ Plan installation to use fewest number of elbows and turns. ■■ When using elbows or making turns, allow as much room as possible. ■■ Bend vent gradually to avoid kinking. [. . . ] For complete details, see Installation Instructions packed with product. [. . . ]